One-Stop Liquid Filling And Packaging Service: Filling Machines, Labeling Machines And Packing Machines Tony007@paima-machine.com

About the adjustment method of filling and capping machine

Views: 182 Author: Paima Publish Time: 2022-10-06 Origin: Site

The filling and capping machine is specially designed for the new type of oral liquid easy-pull bottles and filling equipment. The design is reasonable, the structure is simple, easy to operate, and equipped with a mechanical bottle shortage stop filling device. So, what are the adjustment methods for the filling and capping machine?


plastic-bottle-assembly-line-279photo-Adobe-1540X800.jpg


  1, For the adjustment of the feeding half.

 

  a. Adjust the bottle blocking plate A on the feeding half upward to shorten the bottle feeding stroke; adjust it down to lengthen the bottle feeding stroke.

 

  b. Adjust the positioning bottle position left and right so that the bottle position is correct when the active teeth are running and the bottle is fed into the positioning teeth smoothly.

 

  c. Adjust the bottle stopper plate B to make the width of the bottle inlet ≈ 22 mm or so.

 

  2、For the adjustment of the filling component, the role of the filling component is to make the liquid through the filling device, one-way valve, needle timely delivery to each easy-to-pull bottle, so the needle must be appropriate when entering the bottle mouth, and the filling time should also be appropriate.

 

  a. Adjust the side cam A to turn smoothly or reverse so that the needle is inserted into the mouth of the bottle just before the empty bottle enters the toothed position. And lift the needle before leaving the toothed position.

 

  b. Adjustment of filling time: Turning cam B clockwise or reversing can adjust the needle to start filling liquid immediately after entering the mouth of the bottle and stop filling liquid before the needle leaves the mouth of the bottle.

 

  c. Liquid volume adjustment: loosen nut 1 to adjust the top rod to the D direction, and the liquid volume increases; adjust the liquid volume to the C direction to reduce, while adjusting the nut 2 to the F direction to reduce the amount of liquid, to the E direction to increase the amount of liquid, adjust the limit position of the irrigator, so as not to damage the irrigator, the general irrigator inside the bottom to the drug spit not less than 15 mm is appropriate, the longer the infusion time the better.

 

  3, For automatic stop, filling device working principle and adjustment.

 

  When moving the tooth plate to move the bottle to fill the liquid this block tooth position, cam 7 of the convex surface and swing plate 6 away, swing plate 6 is pulled by the spring 4, for clockwise swing, swing plate 6 then drive the pressure bottle bolts 2 to move down until contact with the bottle 3, at this time should adjust the wire rolling head 5 swing plate 6 contact and adjust the adjusting screw 8 so that the top rod bolts 1 out about 4 mm, this block position appears empty bottle, pressure bottle bolts 2 and swing plate 6 due to the role of the pulling spring 4 continue to move down to make the steel wire rolling head 5 pull the steel wire so that the top rod tether 1 from the top rod 9 so can not drive the filling device work, automatically stop filling the liquid.