The material of the center column of the sleeve labeling machine:

 

Cause of:

 

1. If the control of the folded diameter and thickness of the membrane material is too large or too small, especially in the lower line of the standard size (smaller), it is more likely to cause the center column to jam.

 

2. The clamping point of the central column is too tight, so the label cannot pass through the central column and is stuck.

 

3. When the edge of the cutter returns to the origin every time it turns, it may stop in the groove of the center column, causing the film label to touch the blade and jam the material.

 

4. The groove of the center column may be "cut" by the cutter, resulting in the uneven surface of the center column and the unsmooth subscript, resulting in material jamming.

 

5. When the label is cut off, when it is waiting to be brushed off, the brushing wheel does not successfully insert the cut label into the bottle body, resulting in a domino effect that is reflected back and causes the center column to jam.

 

6. After replacing the new blade, the length is not enough, the label cannot be cut off, and the material cannot be brushed and inserted.

 

 Solution:

 

1. Effectively require label suppliers to do a good job in the control of the folded diameter value and thickness value. The normal required folded diameter is within ±0.5mm as the standard value, the thickness of the short label is not less than 0.035mm, and the thickness of the long label is not less than 0.045mm to be appropriate. The customer must be asked to provide the label to the sleeve labeling machine with the diameter and thickness of the label within the standard value.

 

2. Correctly adjust the strength of the upper and lower driving rubber wheels.

 

3. It is necessary to check whether the origin of the cutter is correct, and check the matching of the whole process control. Be sure to drive the next label within the effective time after the cutter leaves the center column, and the cutter should stop every time it rotates. Stay inside the cutter head and do not get too close to the groove of the center column to ensure that no material is jammed.

 

4. If there is a cut in the groove of the central column, it can be smoothed after the surface treatment.

 

5. To confirm whether the clamping contact between the brush lower wheelset and the center column is indeed not offset and whether the brush lower wheel is worn so that the force under the brush cannot evenly brush the label into the bottle body, otherwise, the label will be Causes a chain reaction to jam the center column.

 

6. Make sure that the length of each blade after the replacement is the same and can just cut off the label, please refer to the old blade before replacement.

 

2. Continuous subscript:

 

Cause of:

 

1. The supporting shrapnel in the lower section of the central column is loose or broken.

 

2. The eye signal of the camera battery is abnormal.

 

  Solution:

 

1. Replace the shrapnel with a new one and adjust it to a suitable stretch to open the label.

 

2. Adjust the sensing position or sensitivity of the electric eye.

 

3. The burrs of the sleeve labeling machine are too heavy:

 

Cause of:

 

Because most of the sleeve labeling machines currently on the market are designed with multiple knives, it is difficult to completely control the burrs.

 

1. The label is too large, and the deviation between the diameter of the center column and the folding diameter of the film material is too large.

 

2. The calibration leveling point of the cutter head is not on the line.

 

3. Inside the cutter head group, the gap between the groove of the eccentric shaft and the bottom of the cutter seat is too large, which causes the blade to be uneven.

 

4. The strength of the blade is not enough.

 

Solution:

 

1. Do a good job in the control of the label size, and confirm that the label folding diameter matches the diameter of the center column.

 

2. Confirmation of flat point after blade replacement, and tightness control of lock blade.

 

3. Just replace the relevant parts inside the cutter set.

 

4. Replace the blade with a new one.