Glass bottle juice beverage filling machine is mainly used for beverage filling operation, combining the three functions of rinsing, filling, and capping in one body, the whole process is automated, suitable for polyester bottles, plastic bottle filling, mineral water, pure water, plus the temperature control device can be hot filling, each part of the applicable bottle type adjustment using the handle rotation to achieve, easy and comfortable, simple and fast.
The process of glass bottle juice beverage filling machine is generally as follows: the boxes with empty bottles are stacked on pallets and sent to the unloading pallet machine by conveyor belt, the pallets are unloaded one by one, the boxes are sent to the unloading machine with the conveyor belt, the empty bottles are taken out from the boxes, the empty boxes are sent to the washing machine by the conveyor belt, after being cleaned, and then transported to the boxing machine in order to fill the bottles with beverages into them. The empty bottles taken out from the case unloading machine are sent to the bottle washing machine by another conveyor belt to be disinfected and cleaned and are inspected by the bottle inspection machine and enter the equipment after meeting the clean standard. The beverage is filled into the bottle by this equipment, and the filled bottle is sealed by a capping machine with a cap and conveyed to the labeling machine for labeling, after labeling it is sent to the boxing machine for loading into the box and then sent to the stacking pallet machine for stacking on the pallet and sent to the warehouse.
Measures after the abnormal rotation of the glass bottle juice beverage filling machine.
The liquid injection is not uniform, the joint is tightened at the end, there is air leakage, and it needs to be tightened can be, if the machine rotates normally, but no dispensing liquid is discharged. First of all, check whether there is any foreign matter inside the valve, if so, it should be cleaned immediately; check whether the upper and lower two thimbles inside the valve are placed incorrectly, the correct method should be that both thimbles are facing downward, and should not be installed in reverse. If the crank does not rotate normally after the power is on. This situation is relatively simple to deal with. The upper fixing rod is biased down, and the inner and outer tubes of the syringe are firmly topped when the liquid is pushed, resulting in the crank not being able to rotate, the nut should be loosened, and the upper fixing rod should be moved upward to an appropriate position, and then the nut should be tightened. If the syringe assembly is not clean and is stuck between the inner and outer tubes, the syringe should be removed for cleaning. Observe the end of the injection system into the bearing part. Make it does not work properly, it is necessary to reassemble it.